1)Black P:Cerebrospinal fluid leaks following spinal surgery:use of fat graft for prevention and repair. Technical note. J Neurosurg 96:250-252, 2002
2)Boogaarts JD, Grotenhuis JA, Bartels RH, Beems T:Use of a novel absorbable hydrogel for augmentation of dural repair:results of a preliminary clinical study. Neurosurgery 57:146-151, 2005
3)Buttes RP, Conley FR:Progressive neurosurgical dysfunction secondary to postoperative cervical pseudomeningocele in a C-4 quadriplegic. Case report. J Neurosurg 48:52-58, 1978
4)Carpenter MB:Core Text of Neuroanatomy, ed 3. Williams and Wilkins, Philadelphia, 1987, pp1-3
5)Cosgrove GR, Delashaw JB, Grotenhuis JA, Tew JM, Van Loveren H, Spetzler RF, Payner T, Rosseau G, Shaffrey ME, Hopkins LN, Byrne R, Norbash A:Safety and efficacy of a novel polyethylene glycol hydrogel sealant for watertight dural repair. J Neurosurg 106:52-58, 2007
6)Eismont FJ, Wiessel SW, Rothman RH:Treatment of dural tears associated with spinal surgery. J Bone Joint Surg Am 63:1132-1136, 1981
7)Ferrante L, Palatinsky E, Acqui M, Mastronardi L:Endaural extracranial repair for cerebrospinal otorrhoea with human fibrin glue:technical note. J Neurol Neurosurg Psychiatry 51:1438-1440, 1988
8)Hino M, Ishiko O, Honda K, Yamane T, Ohta Y, Takubo T, Tatsumi N:Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery. Br J Haematol 108:194-195, 2000
9)Ito K, Ishizaka S, Sasaki T, Miyahara T, Horiuchi T, Sakai K, Shigeta H, Hongo K:Safe and minimally invasive laminoplastic laminotomy using an ultrasonic bone curette for spinal surgery:technical note. Surg Neurol 72:470-475, 2009
10)Kawamura M, Sawafuji M, Watanabe M, Horinouchi H, Kobayashi K:Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery. Ann Thorac Surg 73:1098-1100, 2002
11)Nagata K, Kawamoto S, Sashida J, Abe T, Mukasa A, Imaizumi Y:Mesh-and-Glue technique to prevent leakage of cerebtospinal fluid after implantation of expanded polytetrafluoroethylene dura substitute. technical note. Neurol Med Chir (Tokyo) 39:316-319, 1999
12)Nakamura H, Matsuyama Y, Yoshihara H, Sakai Y, Katayama Y, Nakashima S, Takamatsu J, Ishiguro N:The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery:a randomized controlled trial. Spine 30:347-351, 2005
13)Preul MC, Bichard WD, Spetzler RF:Toward optimal tissue sealants for neurosurgery:use of a novel hydrogel sealant in a canine durotomy repair model. Neurosurgery 53:1189-1198, 2003
14)Preul MC, Campbell PK, Bichard WD, Spetzler RF:Application of a hydrogel sealant improves watertight closures of duralplasty onlay grafts in a canine craniotomy model. J Neurosurg 107:642-650, 2007
15)Shaffrey CI, Spotnitz WD, Shaffrey ME, Jane JA:Neurosurgical applications of fibrin glue:augmentation of dural closure in 134 patients. Neurosurgery 26:207-210, 1990
16)Yoshimoto T, Sawamura Y, Houkin K, Abe H:Effectiveness of fibrin glue for preventing postoperative extradural fluid leakage. Neurol Med Chir (Tokyo) 50:417-420, 2010