1) Babcock DE, Hergenrother RW, Craig DA, Kolodgie FD, Virmani R:In vivo distribution of particulate matter from coated angioplasty balloon catheters. Biomaterials 34:3196-3205, 2013
2) Barnwell SL, D'Agostino AN, Shapiro SL, Nesbit GM, Kellogg JX:Foreign bodies in small arteries after use of an infusion microcatheter. AJNR Am J Neuroradiol 18:1886-1889, 1997
3) Deguchi K, Kawahara Y, Deguchi S, Morimoto N, Kurata T, Ikeda Y, Ichikawa T, Tokunaga K, Kawai N, Sugiu K, Abe K:A patient develops transient unique cerebral and cerebellar lesions after unruptured aneurysm coiling. BMC Neurol 15:49, 2015
4) Fealey ME, Edwards WD, Giannini C, Piepgras DG, Cloft H, Rihal CS:Complications of endovascular polymers associated with vascular introducer sheaths and metallic coils in 3 patients, with literature review. Am J Surg Pathol 32:1310-1316, 2008
5) Grundeken MJ, Li X, Kurpershoek CE, Kramer MC, Vink A, Piek JJ, Tijssen JG, Koch KT, Wykrzykowska JJ, de Winter RJ, van der Wal AC:Distal embolization of hydrophilic-coating material from coronary guidewires after percutaneous coronary interventions. Circ Cardiovasc Interv 8:e001816, 2015
6) Kozak M, Adams DR, Ioffreda MD, Nickolaus MJ, Seery TJ, Chambers CE, Ettinger SM, McNulty PH, Gilchrist IC:Sterile inflammation associated with transradial catheterization and hydrophilic sheaths. Catheter Cardiovasc Interv 59:207-213, 2003
7) Mehta RI, Mehta RI, Solis OE, Jahan R, Salamon N, Tobis JM, Yong WH, Vinters HV, Fishbein MC:Hydrophilic polymer emboli:an under-recognized iatrogenic cause of ischemia and infarct. Mod Pathol 23:921-930, 2010
8) Oh SW, Shin NY, Lee HJ, Kim BM, Kim DJ:Delayed enhancing lesions after coil embolization of aneurysms:clinical experience and benchtop analyses. J Neurointerv Surg 9:1243-1247, 2017
9) 大川原舞,孫 宰賢,山口裕之,山田 創,上田幹也,前田高宏:コイル塞栓術後に脳実質内に多発増強病が出現した1例:親水コーティング塞栓との関連性について.脳血管内治療1:37-43, 2016
10) Park HS, Nakagawa I, Yokoyama S, Wajima D, Wada T, Motoyama Y, Kichikawa K, Nakase H:Nickel-associated delayed multiple white matter lesions after stent-assisted coil embolization of intracranial unruptured aneurysm. J Neurointerv Surg 10:e1, 2018doi:10.1136/neurintsurg-2017-013005.rep
11) Shapiro M, Ollenschleger MD, Baccin C, Becske T, Spiegel GR, Wang Y, Song X, Raz E, Zumofen D, Potts MB, Nelson PK:Foreign body emboli following cerebrovascular interventions;clinical, radiographic, and histopathologic features. AJNR Am J Neuroradiol 36:2121-2126, 2015
12) 庄田健二,木村公俊,米澤慎悟,竹中俊介,原 秀,深澤誠司:コイル塞栓術後に遅発性に生じた症候性の多発性白質病変の1例.脳外誌27:38-44, 2018
13) Skolarus LE, Gemmete JJ, Braley T, Morgenstern LB, Pandey A:Abnormal white matter changes after cerebral aneurysm treatment with polyglycolic-polylactic acid coils. World Neurosurg 74:640-644, 2010