1)Gedde SJ, Schiffman JC, Feuer WJ et al:Treatment outcomes in the Tube Versus Trabeculectomy(TVT)study after five years of follow-up. Am J Ophthalmol 153:789-803, 2012
2)Gedde SJ, Hermdon LW, Brandt JD et al:Postoperative complications in the Tube Versus Trabeclectomy(TVT)study during five years of follow-up. Am J Ophthalmol 153:804-814, 2012
3)Heuer DK, Budeuz D, Coleman A:Aqueous shunt tube erosion. J Glaucoma 10:493-496, 2001
4)Lama PJ, Fechtner RD:Tube erosion following insertion of a glaucoma drainage device with a pericardial patch graft. Arch Ophthalmol 117:1243-1244, 1999
5)Brandt JD:Patch grafts of dehydrated cadaveric dura mater for tube-shunt glaucoma surgery. Arch Ophthalmol 111:1436-1439, 1993
6)Gutierrez-Diaz E, Montero-Rodriqueiz M, Mencia-Gutierrez E et al:Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery. Eur J Ophthalmol 15:412-414, 2005
7)Thakur S, Ichhpujani P, Kumar S:Grafts in glaucoma surgery:a review of the literature. Asia Pac J Ophthalmol 6:469-476, 2017
8)三木美智子・植木麻理・河本良輔・他:バルベルト緑内障インプラントによるチューブシャント手術後に眼内炎を発症した1例.眼科手術30:536-540,2017
9)Nouri-Mahdavi K, Caprioli J:Evaluation of the hypertensive phase after insertion of the Ahmed glaucoma valve. Am J Ophthalmol 136:1001-1008, 2003
10)Jung KI, Park CK:Risk factors for the hypertensive phase after implantation of a glaucoma drainage device. Acta Ophthalmol 94:260-267, 2016
11)Fargione RA, Tansuebchueasai N, Lee R et al:Etiology and management of the hypertensive phase in glaucoma drainage-device surgery. Surv Ophthalmol 64:217-224, 2019
12)Christakis PG, Zhang D, Budenz DL et al:Five-year pooled data analysis of the Ahmed Baerveldt comparison study and the Ahmed Versus Baerveldt study. Am J Ophthalmol 176:118-126, 2017
13)Francis BA, DiLoreto DA, Chong LP et al:Late-onset bacterial endophthalmitis following glaucoma drainage implantation. Ophthalmic Surg Lasers Imaging 34:128-130, 2003
14)AI-Torbak AA, AI-Shahwan S, AI-Jadaan I et al:Endophthalmitis associated with the Ahmed glaucoma valve implant. Br J Ophthalmol 89:454-458, 2005
endophthalmitis following Ahmed glaucoma valve implantation. Jpn J Ophthalmol 49:315-317, 2005
16)Chaku M, Netland PA, Ishida K et al:Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery. Clin Ophthalmol 30:547-553, 2016
17)Bains U, Hoguet A:Aqueous drainage device erosion:A review of rates, risks, prevention, and repair. Semin Ophthalmol 33:1-10, 2018
18)Lee HY, Park JS, Choy YJ et al:Surgical outcomes of different Ahmed glaucoma valve implantation methods between scleral graft and scleral flap. Korean J Ophthalmol 25:317-322, 2011
19)Lankaranian D, Reis R, Henderer JD et al:Comparison of single thickness and double thickness processed pericardium patch graft in glaucoma drainage device surgery:a single surgeon comparison of outcome. J Glaucoma 17:48-51, 2008
20)Smith MF, Doyle JW, Ticrney JW Jr:A comparison of glaucoma drainage implant tube coverage. J Glaucoma 11:143-147, 2002