Multiplanar reconstruction(MPR)-CTに基づく至適腰椎椎弓根スクリュー径選択

著者: 牧野孝洋1 海渡貴司1 藤原啓恭1 米延策雄1

所属機関: 1国立病院機構大阪南医療センター整形外科

ページ範囲:P.11 - P.16

文献購入ページに移動
 至適腰椎椎弓根スクリュー径決定の指標をmultiplanar reconstruction(MPR)-CTを用いて,冠状断椎弓根横径と椎弓根最短径を比較することで検討した.L1・L2では冠状断椎弓根横径と椎弓根最短径に有意差はなかったが,L3・L4・L5では椎弓根横径より椎弓根最短径は統計学的に有意に小さかった.冠状断椎弓根横径をx,椎弓根最短径(至適椎弓根スクリュー径)をyとすると,回帰式はL1・L2はy=x,L3はy=0.88x,L4はy=0.76x,L5はy=0.58xとして求められた.

参考文献

1) Assaker R, Reyns N, Vinchon M, et al:Transpedicular screw placement:image-guided versus lateral-view fluoroscopy:in vitro simulation. Spine 26:2160-2164, 2001
2) Bernard TN Jr, Seibert CE:Pedicle diameter determined by computed tomography. Its relevance to pedicle screw fixation in the lumbar spine. Spine 17(6 Suppl):S160-S163, 1992
3) Bindal RK, Ghosh S:Intraoperative electromyography monitoring in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 6:126-132, 2007
4) Bose B, Wierzbowski LR, Sestokas AK:Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery. Spine 27:1444-1450, 2002
5) Castro WHM, Halm H, Jerosch J, et al:Accuracy of pedicle screw placement in lumbar vertebrae. Spine 21:1320-1324, 1996
6) Cheung KMC, Ruan D, Chan FL, et al:Computed tomographic osteometry of asian lumbar pedicles. Spine 19:1495-1498, 1994
7) Holly LT, Foley KT:Intraoperative spinal navigation. Spine 28(15 Suppl):S54-S61, 2003
8) Kanemura T, Yoshida G, Ishikawa Y, et al:Low triggered electromyographic thresholds for accuracy assessment of lumbar pedicle screw placement. J Spine Res 1:85-90, 2010
9) Krag MH, Weaver DL, Beynnon BD, et al:Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27-32, 1988
10) McLain RF, Fry MF, Moseley TA, et al:Lumbar pedicle screw salvage:pullout testing of three different pedicle screw designs. J Spinal Disord 8:62-68, 1995
11) Nottmeier EW, Seemer W, Young PH:Placement of thoracolumbar pedicle screws using three-dimensional imaging guidance:experience in a large patients cohort. J Neurosurg Spine 10:33-39, 2009
12) Schizas C, Michel J, Kosmopoulos V, et al:Computed tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. Eur Spine J 16:613-617, 2007
13) Schulze CJ, Munzinger E, Weber U:Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis. Spine 23:2215-2221, 1998
14) Skinner R, Maybee J, Transfeldt E, et al:Experimental pullout testing and comparison if variables in transpedicular screw fixation. A biomechanical study. Spine 15:195-201, 1990
15) Tian NF, Xu HZ:Image-guided pedicle screw insertion accuracy:a meta-analysis. Int Orthop 33:895-903, 2009
16) Welch WC, Rose RD, Balzer JR, et al:Evaluation with evoked and spontaneous electromyography during lumbar instrumentation:a prospective study. J Neurosurg 87:397-402, 1997
17) Wiesner L, Kothe R, Schulitz K-P, et al:Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. Spine 25:615-621, 2000
18) Zindrick MR, Wiltse LL, Doornik A, et al:Analysis of the morphometric characteristics of the thoracic and lumbar pedicles. Spine 12:160-166, 1987
19) Zindrick MR, Wiltse LL, Widell EH:A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop 203:99-112, 1986

掲載誌情報

出版社:株式会社医学書院

電子版ISSN:1882-1286

印刷版ISSN:0557-0433

雑誌購入ページに移動
icon up

本サービスは医療関係者に向けた情報提供を目的としております。
一般の方に対する情報提供を目的としたものではない事をご了承ください。
また,本サービスのご利用にあたっては,利用規約およびプライバシーポリシーへの同意が必要です。

※本サービスを使わずにご契約中の電子商品をご利用したい場合はこちら