1) McLaughlin HL. Rupture of the rotator cuff. J Bone Jt Surg 1962;44(5):979-83.
2) Burkhart SS, Athanasiou KA, Wirth MA. Margin convergence:a method of reducing strain in massive rotator cuff tears. Arthroscopy 1996;12(3):335-8.
3) Hersche O, Gerber C. Passive tension in the supraspinatus musculotendinous unit after long-standing rupture of its tendon:a preliminary report. J Shoulder Elbow Surg 1998;7(4):393-6.
4) Davidson PA, Rivenburgh DW. Rotator cuff repair tension as a determinant of functional outcome. J Shoulder Elbow Surg 2000;9(6):502-6.
5) Park MC, ElAttrache NS, Tibone JE, et al. Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Shoulder Elbow Surg 2007;16(4):461-8.
6) Burks RT, Crim J, Brown N, et al. A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair:magnetic resonance imaging and early clinical evaluation. Am J Sports Med 2009;37(4):674-82.
7) Carbonel I, Martinez AA, Calvo A, et al. Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears:a prospective randomized clinical study. Int Orthop 2012;36(9):1877-83.
8) Franceschi F, Ruzzini L, Longo UG, et al. Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears:a randomized controlled trial. Am J Sports Med 2007;35(8):1254-60.
9) Koh KH, Kang KC, Lim TK, et al. Prospective randomized clinical trial of single- versus double-row suture anchor repair in 2- to 4-cm rotator cuff tears:clinical and magnetic resonance imaging results. Arthroscopy 2011;27(4):453-62.
10) Lapner P, Li A, Pollock JW, et al. A multicenter randomized controlled trial comparing single-row with double-row fixation in arthroscopic rotator cuff repair:long-term follow-up. Am J Sports Med 2021;49(11):3021-9.
11) Ma HL, Chiang ER, Wu HT, et al. Clinical outcome and imaging of arthroscopic single-row and double-row rotator cuff repair:a prospective randomized trial. Arthroscopy 2012;28(1):16-24.
12) Cho NS, Yi JW, Lee BG, et al. Retear patterns after arthroscopic rotator cuff repair:single-row versus suture bridge technique. Am J Sports Med 2010;38(4):664-71.
13) Gerber C, Meyer DC, Schneeberger AG, et al. Effect of tendon release and delayed repair on the structure of the muscles of the rotator cuff:an experimental study in sheep. J Bone Joint Surg Am 2004;86(9):1973-82.
14) Meyer DC, Farshad M, Amacker NA, et al. Quantitative analysis of muscle and tendon retraction in chronic rotator cuff tears. Am J Sports Med 2012;40(3):606-10.
15) Meyer DC, Wieser K, Farshad M, et al. Retraction of supraspinatus muscle and tendon as predictors of success of rotator cuff repair. Am J Sports Med 2012;40(10):2242-7.
16) Dierckman BD, Frousiakis P, Burns JP, et al. Arthroscopic repair of medium to large rotator cuff tears with a triple-loaded medially based single-row technique augmented with marrow vents. Arthroscopy 2021;37(1):28-37.
17) Yamakado K. A prospective randomized trial comparing suture bridge and medially based single-row rotator cuff repair in medium-sized supraspinatus tears. Arthroscopy 2019;35(10):2803-13.
18) Dierckman BD, Wang DW, Bahk MS, et al. In vivo measurement of rotator cuff tear tension:medial versus lateral footprint position. Am J Orthop (Belle Mead NJ) 2016;45(3):E83-90.
19) He HB, Hu Y, Li C, et al. Biomechanical comparison between single-row with triple-loaded suture anchor and suture-bridge double-row rotator cuff repair. BMC Musculoskelet Disord 2020;21(1):629. doi:10.1186/s12891-020-03654-y.
20) Pastor MF, Kraemer M, Schwarze M, et al. The effect of rotator cuff malreduction on tendon tension:an evaluation of a custom-made digital tensiometer clamp. Arch Orthop Trauma Surg 2018;138(2):219-25.
21) Kim DH, Jang YH, Choi YE, et al. Evaluation of repair tension in arthroscopic rotator cuff repair:does it really matter to the integrity of the rotator cuff? Am J Sports Med 2016;44:2807-12.
22) Park SG, Shim BJ, Seok HG. How much will high tension adversely affect rotator cuff repair integrity? Arthroscopy 2019;35(11):2992-3000.
23) Takeda Y, Fujii K, Suzue N, et al. Repair tension during arthroscopic rotator cuff repair is correlated with preoperative tendon retraction and postoperative rotator cuff integrity. Arthroscopy 2021;37(9):2735-42.
24) Yokoya S, Nakamura Y, Harada Y, et al. Effectiveness of measuring tension during arthroscopic rotator cuff repair. J Exp Orthop 2021;8(1):21. doi:10.1186/s40634-021-00341-2.
25) Uno T, Mura N, Yuki I, et al. Factors correlated with the optimal tension for arthroscopic rotator cuff repair using Grasper Tensioning Attachment. J Shoulder Elbow Surg 2021;31(5):e213-22. doi:10.1016/j.jse.2021.10.004.
26) Shibata T, Izaki T, Nishio J, et al. Are there differences in arthroscopic and histological features between traumatic and degenerative rotator cuff tears in elderly patients? A prospective dual-center analysis. J Orthop Surg Res 2022;17(1):206. doi:10.1186/s13018-022-03100-w.
27) Miyake S, Izaki T, Arashiro Y, et al. Excessively high repair tension decreases microvascular blood flow within the rotator cuff. Am J Sports Med 2022;50(13):3643-8.
28) Mizuki Y, Senjyu T, Ito T, et al. Extreme medialized repair for challenging large and massive rotator cuff tears reveals healing and significant functional improvement. Arthroscopy 2023;S0749-8063(23)00306-7. doi:10.1016/j.arthro.2023.03.030.